PO Box 990 Ripon, WI 54971-0990 (920) 748-3121Page 1 of 18 FB08-15BULLETINFieldBulletin No. FB08-15Date July 2008Product Type IPSO and Cis
Error CodesPage 10 of 18 FB08-15A9 Motor thermal protector was activated.• Check the following: a. motorb. motor connectionsc. contactorsd. input volt
Error CodesFB08-15 Page 11 of 18Table 5FH There is a hardware problem (fault on printed circuit board) •Replace print boardError Code Probable Cause P
Error CodesPage 12 of 18 FB08-15Control Type: SIGMATable 6Error Code Probable Cause Possible Corrective ActionsE3 (E Prom) E Prom has a faulty value.
Error CodesFB08-15 Page 13 of 18Additional information for SIGMA• BOOT 100 appears on the display during Start up or Boot Memory - E Prom. • Additiona
Error CodesPage 14 of 18 FB08-15Control Type: DX4NOTE: If there is a gas failure the electronic ignition of the gas heated tumbler will only try to fu
Error CodesFB08-15 Page 15 of 18Control Type: CygnusNOTE: Errors 1-32 display only when a Cygnus control machine is NOT running.Error Code Probable Ca
Error CodesPage 16 of 18 FB08-15ERROR 13 (Temperature Error) At startup, the temperature is higher than 95o C or after 6 minutes the temperature is st
Error CodesFB08-15 Page 17 of 18Table 8NOTE: Errors 50-59 display only when a Cygnus control machine IS running.ERROR 26 (New ID Chip Error) Error whe
Error CodesPage 18 of 18 FB08-15Table 9ERROR 52 (Drain Error) Water level is not lowered within 2cm after 2 minutes upon completion of a wash cycle (M
Error CodesPage 2 of 18 FB08-15Control Type: Micro 9NOTE: In the event of an error the control will generate an error message at the end of the cycle.
Error CodesFB08-15 Page 3 of 18NOTE: * To clear the not 3 error code: coin or vended machines - go to program D and press ECO button (E). OPL models -
Error CodesPage 4 of 18 FB08-15Control Type: Micro 20NOTE: When a malfunction occurs during a program, the central display will communicate the approp
Error CodesFB08-15 Page 5 of 18Table 3EA (tilt switch) Tilt switch was activated 15 times, skipping the final spin.•Check load size and type• Inspect
Error CodesPage 6 of 18 FB08-15Control Type: PC30Error Code Probable Cause Possible Corrective Actions00 Programming key in wrong place.•Correct posit
Error CodesFB08-15 Page 7 of 18Table 411 Level switch detects water in the drum at the start of a cycle.•Inspect inlet water valves• Inspect drain val
Error CodesPage 8 of 18 FB08-15Additional information for the PC30 and KEB Frequency Controller• There is a test program built into the PC30 - the acc
Error CodesFB08-15 Page 9 of 18Control Type: PS40 and PS40FNOTE: Alarm codes are used to alert the operator to problems with the machine function. The